Current Probe
-
- 10Hz-2MHz bandwidth
- Measurement 1mA to 1200A AC
- Low phase shift
- Diameter: φ52mm
- EN 61010, 600V CAT III
- High precision 0.1%
-
- 10Hz-2MHz bandwidth
- Diameter: φ120mm
- Cable fault analysis
- EN 61010, 600V CAT III
- Measurement 0 to 3000A AC
- Leakage current measurement
-
- Cable fault analysis
- Leakage current measurement
- 10Hz-200kHz bandwidth
- Measurement 0 to 3000A AC
- Diameter: φ150mm
- EN 61010, 600V CAT III
-
- Accuracy 0.1%
- UL, CE mark
- Low phase shift
- Nickel metal core
- EN 61010, 600V CAT III
- Current range from 1mA to 200A
-
- diameter: φ110mm
- Lower phase shift
- CNAS, UL, CE mark
- 10Hz-2MHz bandwidth
- EN 61010, 600V CAT III
- Measurement 0 to 1200A AC
-
- Accuracy 0.1%
- Low phase shift
- UL, CE CNAS mark
- 1mA to 1200A range
- Harmonic measurement
- EN 61010, 600V CAT III
-
- UL, CE mark
- Low phase shift
- Ergonomic design
- 1mA to 20A range
- Nickel metal core
- EN 61010, 600V CAT III
-
- Load capacity: ≤20Ω
- Installation: clamp type
- 1mA-120A current range
- Min 1mA measurement
- 10Hz to 2MHz bandwidth
- Holding wire diameter: φ13mm
-
- Ergonomic design
- Load capacity: ≤20Ω
- 1mA-240A current range
- 10Hz to 2MHz bandwidth
- Installation: clamp type
- Holding wire diameter: φ20mm
-
- Permalloy core
- Ergonomic design
- Lower phase shift
- Load capacity: ≤10Ω
- EN 61010, 600V CAT III
- 5A, 10A cable measurement
-
- Permalloy core
- Ergonomic design
- Lower phase shift
- Load capacity: ≤20Ω
- EN 61010, 600V CAT III
- 1mA to 12A current range
-
- Permalloy core
- Ergonomic design
- UL, CE CNAS mark
- Lower phase shift
- EN 61010-2-032, 600V CAT III
- current range from 1mA to 20A
-
- UL, CE, CNAS mark
- Lower phase shift
- Small, compact size
- 40Hz to 200kHz response
- 1mA/A AC output signals
- High content nickel metal core
-
- Accuracy 0.1%
- Low phase shift
- 1mA to 200A range
- 2000:1 or 2500:1 ratio
- EN 61010, 600V CAT III
- Economical current clamp
-
- Ergonomic design
- Lower phase shift
- Nickel metal core
- Harmonic measurement
- EN 61010-2-032, 600V CAT III
- Current range from 1mA to 120A
-
- Lower phase shift
- Load capacity: ≤20Ω
- Harmonics measurement
- 1mA-600A current range
- 10Hz to 200kHz bandwidth
- Holding wire diameter: φ40mm
-
- Low phase shift
- Jaw diameter: φ50mm
- High precision 0.1%
- Measurement 1mA to 1000A AC
- EN 61010-2-032, 600V CAT III
- 10Hz-200kHz frequency bandwidth
-
- Jaw diameter: φ60mm×70mm
- Measurement 1mA to 1000A AC
- EN 61010-2-032, 600V CAT III
- 10Hz-2MHz frequency bandwidth
- Oscilloscope current measurement
- Low phase shift for power measurement
-
- Lower phase shift
- Jaw diameter: φ110mm
- Improved ergonomic design
- Measurement 1mA to 1500A AC
- EN 61010-2-032, 600V CAT III
- 10Hz-20kHz frequency bandwidth
-
- Jaw diameter: φ120mm×50mm
- Improved ergonomic design
- Measurement 1A to 3000A AC
- EN 61010-2-032, 600V CAT III
- Bus bar jaw opening designed
- Low phase shift for power measurement
-
- Lower phase shift
- Jaw diameter: φ125mm
- Improved ergonomic design
- Measurement 1A to 3600A AC
- Large jaw opening designed
- EN 61010-2-032, 600V CAT III
-
- Jaw diameter: φ150mm
- Cable fault analysis
- Improved ergonomic design
- Large jaw opening designed
- Measurement 1A to 3000A AC
- EN 61010-2-032, 600V CAT III
-
- Low phase shift
- EN61010-2-032:2012
- 40Hz-5kHz bandwidth
- High precision 0.1%
- Excellent linearity
- 1mA to 130A AC range
-
- Maximum 600A
- Light weights
- EN61010-2-032:2012
- High precision 0.1%
- Excellent linearity
- Exquisite appearance
-
- 200mm, 280mm, 350mm
- 0-10KA current range
- 0.1Hz-2MHz frequency
- Excellent linearity 0.2%
- Easy & quick installation
- Flexible and light weights
-
- 40mm, 60mm, 100mm
- 0.1Hz-10MHz frequency
- 0-100KA current range
- Easy & quick installation
- Excellent linearity 0.2%
- Flexible and light weights
-
- Coil diameter 8mm
- EN61010-2-032:2012
- 6000A/3V or 3000A/3V
- 0.1Hz-2MHz bandwidth
- Excellent linearity 0.2%
- Easy & quick installation
-
- Diameter 20mm
- Low phase shift 0.1°
- EN 61010, 600V CAT III
- 0-100A/0-200A current range
- Frequency range DC to 200kHz
- 10mV/A or 1mV/A signal output
-
- Low phase shift 0.1°
- EN 61010, 600V CAT III
- 0-500A/0-1000A current range
- 10mV/A, 1mV/A signal output
- Frequency range DC to 200kHz
- AC and DC current measurement